EQUIPMENT DATA SHEET Spec No
ES.40.03
Project : Coal To Ammonia(CTA), Haldia. Sheet 1 of 1
Equipment Booster Compressor
Quantity 1 Nos
Equipment Number -
Application Pressure Boostup of Syngas
Location Haldia, India.
Manufacturer -
-
Days of operation 340
Design Specification
Compressor Type Steam driven Turbo Compressor
Available Steam temperature (deg C) 515 deg C
Available Steam Pressure (ata) 87
Condenser cooling water inlet Temperature (0 C) 30
Condenser cooling water outlet Temperature (0 C) 40
Ambient Dry Bulb Temp Max / Min (0 C) 40/7
Relative Humidity of Air 70%
Duty requirements(hrs/annum) 8160
The maximum Noise pressure 85db(A)
Input Condition
a)Syngas Analysis,vol % .
CO2 16.00
CO 41.70
H2 31.20
CH4 7.40
CnHm 0.50
H2S+COS 0.20
N2+Ar 3.00
Total 100.00
b) Gas Volume,Nm3/hr 1,28,200
c) Gas Pressure, bar (a) 31
Output requirement
a)Syngas Analysis, Vol % Same as input condition
b)Gas Volume,Nm3/hr 1,28,200
c) Gas Pressure, bar (a) 55.1
Utility requirement
Steam Vendor to specify
Water Vendor to specify
Power Vendor to specify
Comments:-
i)List out the exclusions from your scope of supply
ii)Provide Reference list.
iii)Provide area requirement.
iv)Indicate delivery period.
|