Members:
38102
Current Ads:
23630
English
Chinese
Agilent AOI SJ50 year 2007
:105/5
Posted by:
FixTrade
Location:
Europe - Netherlands
Ad Status:
Active
Manufacturer:
Type:
Model:
SJ50
Year (or range of years):
2005 2006 2007
Condition:
good / excellent
Price (in US dollars):
USD
Quantity:
5
Type of Seller:
Dealer Owner
Description:
Specifications
● Functionality
Post-solder Inspection:
Missing, offset & skewed components. Tombstones. Billboards. Lifted & bent leads.
Excess & Insufficient Solder. Bridging. Polarity. OCR OCV.
Pre-reflow Inspection:
Missing, offset & skewed components. Billboards. 2D paste. Polarity. OCR OCV.
Speed of Operation:
> 25cm2/sec (4in2/sec).
Training/Set-up:
Standard component library. Auto colour presence/absence training.
Auto learning of new coloured parts. Self-learning algorithms.
CAD Conversion:
Agilent CAMCAD professional, recommended CAD translation tool.
● Computer and Software System
Operating Environment:
Windows NT? 4.0 with GUI and password protected user levels.
Computer System:
High speed, Intel� Pentium� based PC. 15" Flat screen monitor. Thin wire or
twisted pair Ethernet networking. High speed PCI bus image framestore.
Vision Algorithms:
Agilent proprietary image analysis techniques. Feature extraction based algorithms.
Geometric component measurement. Colour inspection. Sub-pixel resolution.
● Hardware System
Camera/Lighting System:
Large area digital CCD camera. Electronic shutter. Distortion free gauging lens.
32mm x 25mm field of view at 25μm pixel size.Triple colour, multiple angle LED
lighting head.
Board Dimensions:
Min./max. board size: 50 x50/490 x490 mm.
Max. inspectable area: 480 x 480 mm.
Clearance: Bottom: 50mm, Top: 26 mm (41 mm optional).
Edge clearance: 3.5 mm.
Max. board thickness: 4mm.
Max. board weight: 3 kg.
XY Robot System:
High accuracy linear motor XY gantry for camera positioning.
Dimensions:
Width: 1000mm. Depth: 1520mm. Height: 1405mm - 1540mm.
PCB conveyor height: 821-965 mm.
Weight: 1500kg.
Supplies:
200V - 240V (25A) or 100V - 120V (40A). Clean filtered air at 5bar.
Operating Temperature:
100C to 350C.
Standard SMEMA communication
Ad Number: 163869
About this Agilent SJ50 listing - This is a for sale classified ad for a used, surplus or second hand Agilent SJ50 equipment. It is posted by one of our members. To contact the seller of this item please click the WebMail icon at the bottom of this Agilent SJ50 listing or view this user's member profile for detailed contact info.