PowerLogger 10
PowerLogger10 multimeter is a power quality troubleshooting tool, as well as a high performance precision instrument for laboratory use, service and training. With a display range of 300,000 counts, as well as outstanding accuracy and long-term stability, it fulfills all requirements for use in calibration and R&D laboratories. The instrument can be utilized on-site for precision maintenance and calibration tasks thanks to battery operation.
Features & Highlights
310,000 Count 5 3/4 Digit
Package Contents: Meter, three voltage test leads, large hard case, USB interface adaptor and cable, DranWin10 Software, spare fuse pack, user manual
* Voltage 600 V and current 10 A (Rms or DC) max measurements
* Frequency, RMS value of AC measuring voltage
* DC measurement precision, 5¾ places ( 309,999 counts)
* AC measurement precision, 4¾ places ( 30,999 counts)
* Power and Energy measurements (W, VAr, VA, Wh, VArh, PF)
* Maximum value for periodic power with date and time
* RMS Waveshape, allows for waveshape independent measurement (TRMS AC and AC+DC) up to 100 kHz, and up to a crest factor of 5.
* Power disturbance recording
* Data memory capable of storing 60,000 mesaured values
* Triple display allows momentary measured value and up to two additional values are displayed simultaneously
* Momentary, minimum and maximum measured values
* Continuity testing with audible signal to indicate connectivity
* Event counting (number and duration), zero-crossings, stopwatch, and data-compare.
* Capacitance measurement to 300 uF
* Resistance measurement to 15 meg ohms
* Temperature measurement in degrees Fahrenheit or Celsuis
* Thermocouple measurement capabilibities of Type J and K thermocouples
* Battery run time, approximately 100 hrs on 2 AA alkalines
* Low battery indicator automatically displayed if battery voltage drops below 2.3 V
* Overload Protection, audible sound is employed if upper voltage or current range is exceeded
* Fuse indicator displays message that the fuse for current measurements needs to be replaced
|