Description: |
| |
|
HP/Agilent 6612B 40 Watt DC Power Supply
The units are guaranteed to work for 30-days, parts and labor, excluding freight.
Key Features:
# Precision low current measurement
# Low-output noise
# High-speed programming
# HP-IB and RS-232 interface
# SCPI (Standard Commands for Programmable Instruments)
Specifications (at 0°C to 55°C unless otherwise specified):
Output Ratings:
Voltage: 0 to 20 V
Current: 0 to 2 A
Programming Accuracy (0.05%+):
Voltage: 10 mV
+Current: 1 mA
Ripple and Noise (20 Hz to 20 MHz, with outputs ungrounded or with either terminal grounded):
Voltage - Normal Mode (rms/p-p): 0.3 mV/3 mV
Voltage - Fast Mode (rms/p-p): NA
Current (rms): 1 mA
DC Measurement Accuracy (via HP-IB or front panel meters with respect to actual output at 25°C ±5°C):
Voltage (0.3%+): 3 mV
Low Current Range:
-20 mA to +20 mA (0.1%+): 2.5 µA
High Current Range:
+20 mA to + rated I (0.2%+): 0.25 mA
-20 mA to - rated I (0.2%+): 0.85 mA
Load Regulation:
Voltage: 2 mV
Current: 0.5 mA
Line Regulation:
Voltage: 0.5 mV
Current: 0.5 mA
Transient Response Time: Less than 100 µs (50 µs in the fast mode) for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply) following any step change in load current of up to 50% of the output current rating of the supply
Supplemental Characteristics:
Average Programming Resolution:
Voltage: 5 mV
Current: 0.5 mA
Sink Current*: 1 A
Minimum Current in Constant Current Mode: 8 mA
DC Floating Voltage: Output terminals can be floated up to ±50 VDC maximum from chassis ground
Remote Sensing: Up to two volts dropped in each load lead. Add 2 mV to the voltage load regulation specification for each one volt change in the positive output lead due to load current change.
Command Processing Tim: Average time required for the output voltage to begin to change following receipt of digital date is 4 ms for the power supplies connected directly to the GPIB (display disabled).
Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 2 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 6 ms (2 ms in the fast mode).
GPIB Interface Capabilities: IEEE-488.2, SCPI command set, and 6630A Series programming compatibility
Instrument Time: Averaging time to make a voltage or current measurement is 50 ms.
Input Power (Full Load): 160 VA, 100 W
Regulatory Compliance: Listing pending to UL3111-1; certified to CSA22.2 No. 1010.1; conforms to IEC1010-1; complies with EMC directive 89/336/EEC (ISM Group 1, Class B)
Size: 212.8 mm W x 88.1 mm H x 425.8 mm D (8.4 in x 3.5 in x 16.8 in)
Weight: 8.85 kg (19.5 lb)
Notes:
*: The sink current does not track the programmed current for the HP 6612B. Sink current is fixed at 1A.
**: When programming in the HP 6630A Series language compatibility mode.
|
This ad has been Closed!
We are sorry but this ad is not available at present; possible reasons for this include:
1. It is an old ad and has been closed by the system.
2. It has been marked as SOLD or FOUND by the poster.
Don't let this stop you though, we have many other similar ads.
Quick Links:
1. Browse Ads
2. Search Ads
3. Registration is Free